The Impactsee log Precision Instrument Edition 2.3is the flagship model in the prmierse series of impact recorders , Portable Precision Instrument Edition 2.3serials products are loggers that collect and monitor various data such as temperature , humidity , illumina - tion , tilt value , vibration value , position , etc . based on CAT .1_4G communication technology and ITO technology
The equipment can realize 7x24 hours uninterrupted cton and monitoring . The collected data can be uploaded to the cloud platform in time for real - time monitoring .
The equipment is characterized by small size , light weight , long standby time , portable installation , accurate data , safe use , etc . It is widely used in the transportation or storage of medicine and healthcare , cold chain freshness , aerospace , electronic semicon - ductors , valuables and other fields .
The impactsee log is a highly durable impact recorder that can be configured to monitor critical parameters , providing an unmistakable alert that an impact to a shipment or equipment may have compromised its integrity , performance , or safe operation .
Identify Incidents Before Delivery or Installation Impactsee log delivers alerts that your product has encountered conditions that might affect its performance or safety , enabling immediate inspection and remediation at the time shipment is received or before installation in the field .
Protect Your High Value Assets
Customers use the Impactsee log impact recorder to :
· Ultra - long standby time ,60 minutes to report can last up to 70 days
● Accurate positioning , supporting GPS / Beidou and base station positioning ;● Accurate collection , equipped with international brand temperature and humidity sensor ,6- axis sensor and illumination sensor ;
· Create waybill with one click , convenient one - click creation or cancellation of waybills · Upgrade Assurance , supporting remote upgrade and local upgrade
· Multiple working modes , supplying low power , flight , normal , waybill etc . modes
· Convenient installation , mushroom stickers , blisters and other mounting accessories are available for selection
· Safety in use , remote shutdown anti - cheating ,IPX5 protection
· Alert recipients and operators to inspect goods and equipment for potential damage · Determine baseline damage boundaries
· Detect mishandling during shipping , operation and storage , enabling you to identify and assign accountability and take corrective action
· Make adjustments to product packaging , loading process , carriers , or mode of transport
· Help identify opportunities for improvement through journey profiling
The Impactsee log is designed for applications where a variety of conditions are to be monitored Below is a small sampling of applications in which the Impactsee log has been used :
· Automotive parts : Motors , pumps , windshields , engines , transmissions
· Transportation : Rail cars , barges , cranes , and trucking fleets
· Energy : Oil and gas drilling tools , power transformers , nuclear materials , solar panels , and wind turbines
· Defense and aviation : Lasers , missiles , munitions , gyroscopes , aircraft engines , rocket boosters , and satellites
· Medical and research : Lab equipment , particle accelerator systems , MRI machines , dental chairs , x - ray equipment
① waybill button
short press for 1 second to view the status of each indicator light , off after 3 seconds
· Create waybill , press and hold for 3 seconds , the buzzer sounds 2 times and turns into a blue light to create a successful waybill
. Closing waybill , press and hold for 3 seconds , the buzzer sounds 2 times and turns green to indicate that the end of the waybill is successful . Operating light flashing blue , indicates that the waybill is in progress . Operating light flashing green , indicates that the device not in waybill · Failure to operate a waybill , no change of working indicator , no buzzer sound ;
② status indicator
short press the waybill button for 1 second , the indicator light will turn on for 3 seconds and then turn off
. Green indicator light always on , not in waybill status
· Blue indicator light always on , in waybill progress
· Red light on , communication anomaly
. Red light flashing , flight mode
③ battery indicator
short press the waybill button for 1 second , the indicator light will turn on for 3 seconds and then turn off
· Indicator flashing , indicates charging , more indicator lights means more power ,4 means full charge ;
· Indicator always on , more indicator lights means more power ,4 means full charge
. All lights off , in power off status
Battery indicator off , low power mode
④ light - sensitive window
for Illumination data collection
⑤ switch
when the power is off , long press the power button for 5s to turn on the power .0-2S shows the power level of the device ,2-5S the power indicator lights up one by one , at 5S the buzzer rings once and the power - on operation is completed
. Power off , under power - on condition , long press the power button for 5s to turn off the power .0-2S shows the power level of the device ,2-5S the power indicator light is off one by one ,5S when the buzzer sounds , the shutdown operation is completed
⑥ USB charging port connect 5V/2A power adapter
⑦ sticker orange